TitleProduct

Air Particulate Matter Sensor

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2022-06-02 16:29

  • Browse the number:

    414

Send an inquiries

Company Profile

Guangzhou Luftmy Intelligence Technology Co., Ltd

By certification [File Integrity]

Contact:luftmy(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website:http://www.luftmysensor.com/ http://luftmy.lf-changda.com/

Product Details


The GDS06 infrared PM2.5 dust sensor uses the principle of optical scattering to obtain the particle concentration. Because the particles and molecules will scatter light under the irradiation of light, and at the same time will absorb part of the energy of the irradiated light. When a beam of parallel monochromatic light is incident on the particle field under test, it will be affected by scattering and absorption around the particle, and the light intensity will be attenuated. The relative attenuation rate of incident light passing through the concentration field to be measured can be obtained. The relative attenuation rate can basically linearly reflect the relative concentration of dust in the test field. The magnitude of the light intensity is proportional to the strength of the electrical signal converted by photoelectric conversion. By measuring the electrical signal, the relative attenuation rate can be obtained, and then the concentration of dust in the field to be measured can be measured, and then the single-chip microcomputer is used for PWM and UART communication.


Infrared PM2.5 ensor application Field


◆ Air conditioner

◆ Air purifier

◆ Portable detector

◆ Other household appliances

◆ Vehicle air purification

◆ Fresh air system

◆ Intelligent detector

◆ In principle, this product is only suitable for the above-mentioned application fields. When it is used for other purposes, users need to verify it by themselves.

◆ Please keep this product away from the source of high frequency and high voltage as far as possible to avoid the interference caused by high frequency and high voltage.

◆ Irregular violent vibration will increase the measurement error of this product.

◆ External light will increase the measurement error of this product, so when installing it in the device, try to avoid the incident of external light.

◆ Do not block the detection hole of this product or enter large particles. Please install it behind the filter screen when using it. Recommended filter mesh diameter: 10--20μm Thickness: 3--5mm.



Specification


Detection principle

Principle of Infrared Light Scattering

Detection particle size range

0.3~10μm

PM2.5 output consistency

>100ug/m³ Maximum allowable error±15%

<100ug/m³ Maximum allowable error±15ug/m³

PM2.5 output range

0~500

working conditions

-10~65℃, 0~95%RH

Storage conditions

-20~80℃, 0~95%(Non condensing)

Operating Voltage

DC 5V ±0.2V(power ripple 50mV Max)

Working curren

≤20mA

Standby current

≤0.1mA

Output mode

PWM、UART

Mean time to failure(MTTF)

≥3year

Receiving board size

W47*H35*D19(mm)



Sensor Recommendations


1) The installation should be in a position with air circulation;

2) Air velocity: 1.5~3 m/S Air volume: 0.004~0.01 CMM

3) Please put the LUFTMY logo on the top when installing;

4) When installing the sensor on the front, please keep at least 5mm of space in front of the sensor ventilation hole unobstructed;

5) It is recommended to attach 3 to 5 mm thick black breathable filter cotton to the ventilation hole where the sensor is close to the air inlet of the machine during installation to prevent the accumulation and blockage of large particles such as dust and dander;

6) Please install it in the backlight place as much as possible.


http://www.luftmysensor.com/